Brief Description: Assembling and Sealing the Tank (LH)
Fay installed stiffeners by first spreading a thin layer of sealant to the inside of the skin at the stiffener position, as well as over the contact surface of the stiffeners. Installed with 100% clecos until sealant dried. Fabricated Fuel Vent Line for LH tank.
Stiffeners installed with 100% clecos
Fuel Vent Line
Installed Vent Line to test fit final position and location